Nero Buffer Tank

They are suitable for heating systems incorporating all manner of heat sources, including ground and air source heat pumps, biomass boilers, as well as liquid-fuelled or gas-fired appliances. High insulation levels reduce product heat loss, offering enhanced thermal efficiency, reduced heating system cycling, and providing consistent, demand-oriented heating system performance.

Buffer Tank Stats

Model BT110 BT200
Model BT110 BT200
Dimensions
(A) Height (mm) 830 1380
(B) Flow Connections (mm) 530 1080
(C) Thermostat Pocket (mm) 530 868
(D) Return Connections (mm) 257 257
Operating Data
Rated Volume (litres) 107 194
Weight when full (kg) 140 240
Standing heat loss (kWh/24h) 1.43 1.78

Perfectly Paired With...

Zeno R32 Air Source Heat Pumps

AS01 / AS02 / AS03

Available in 3 outputs from 8 - 20kW using a variable speed-inverter driven Panasonic compressor.

View Range

Nero Heat Pump Cylinder

HP170UV / HP200UV / HP240UV / HP290UV
  • Inlet group, complete with strainer, pressure-reducing valve and balanced cold connection
  • Incoloy 3kW immersion heater (s)
  • A 2 Port zone valve (except direct models)
  • Expansion vessel complete with hanging bracket
View cylinder details

Discover more download our brochure.